Case number | Laterality | WTW Orbscan IIz (mm) | WTW Topolyzer (mm) | ACD Orbscan IIz (mm) | ACD Oculyzer (mm) | ICL power (D) | Toric ICL (D) | ICL size based on dataset 1 (mm) | ICL size based on dataset 2 (mm) | Actual postoperative vault* (µm) | Presumed postoperative vault† (µm) |
1 | OD | 11.5 | 11.7 | 3.12 | 3.17 | −11.0 | 1.0 | 12.60 | 13.20 | 780 | 1330 |
1 | OS | 11.4 | 11.7 | 3.08 | 3.10 | −11.5 | 0 | 12.60 | 13.20 | 800 | 1350 |
2 | OS | 11.4 | 11.1 | 3.20 | 3.23 | −9.5 | 1.0 | 12.60 | 12.10 | 390 | 0 |
3 | OD | 11.6 | 11.7 | 3.12 | 3.16 | −8.0 | 0 | 12.60 | 13.20 | 490 | 1040 |
4 | OD | 11.6 | 11.7 | 3.33 | 3.40 | −11.0 | 0 | 12.60 | 13.20 | 610 | 1160 |
4 | OS | 11.5 | 11.8 | 3.35 | 3.38 | −14.0 | 0 | 12.60 | 13.20 | 450 | 1000 |
5 | OD | 11.5 | 11.7 | 3.39 | 3.46 | −15.0 | 1.5 | 12.60 | 13.20 | 790 | 1340 |
6 | OS | 11.8 | 11.6 | 3.00 | 3.05 | −13.0 | 4.5 | 13.20 | 12.60 | 670 | 120 |
*Calculating ICL size based on dataset 1 (from Orbscan IIz),
†=Calculating ICL size based on dataset 2 (from Topolyzer and Oculyzer).
ACD, anterior chamber depth ; ICL, implantable collamer lens; OD, oculus dexter (right eye); OS, oculus sinister (left eye); WTW, white-to-white .