National application of the European visual field standards for driving: a survey study
•,,,.
...
Abstract
Aims To provide an overview of how the European visual field standards for driving (specified in Commission Directive 2009/113/EC) are applied and determine whether individuals with visual field defects are treated equally across Europe.
Methods One ophthalmic expert from each of 32 European countries was invited to participate in an electronic survey. They were presented with threshold and Esterman perimetry results of 15 cases of visual field defects and asked to classify each case as either passed or failed in reference to their national standards. The results were compared with the European Driving Test Group 1 (EDT1), which is a new perimetry algorithm that adheres to the recommendations by the Eyesight Working Group. Fleiss’ kappa was used to determine the inter-rater agreement.
Results Twenty-five countries responded. Three of 15 cases were passed by all. Full agreement on a failed case was not reached. Denmark graded most leniently and passed 12 cases. Bulgaria, Romania and Slovakia graded most strictly and passed five cases. The Fleiss’ kappa score was 0.52 (95% CI 0.49 to 0.55). Only Slovenia was in full agreement with the EDT1. Fifteen countries endorsed specific perimetric tests for assessing fitness to drive. Five of these also defined pass/fail criteria.
Conclusion The directive fails to establish a uniform approach to the visual field requirements, as evident by moderate pass/fail agreement between the national experts. Because the visual standards for driving are enforced differently, identical visual field loss can result in either revocation or approval of a driving license.
Key messages
What is already known about this subject?
The Commission Directive 2009/113/EC defines the visual standards for driving in Europe.
The directive places emphasis on the visual field but omits to establish which perimetry algorithm should be used and how its results should be interpreted.
What are the new findings?
There is only a moderate level of agreement for determination of pass/fail of visual fields between national experts.
The directive is enforced differently between European member states through the use of a variety of perimetry programmes.
In consequence, identical visual field loss can result in either revocation or approval of a driving licence.
How might these results change the focus of research or clinical practice?
A uniform traffic perimetry algorithm should be used to make certain that the visual field is consistently evaluated.
Introduction
The European Union (EU) has adopted the Swedish Vision Zero initiative and aims at reducing road deaths to almost zero by 2050.1 2 A key legislation in this regard is the Commission Directive 2009/113/EC, which defines medical standards for European drivers.3 Notably, each EU member state is required to incorporate these standards into its national law. Driving safely warrants adequate eyesight, and accordingly the directive places particular emphasis on the visual acuity and visual field. For holders of group 1 driving licenses (car and motorcycle), the binocular best-corrected visual acuity (BCVA) must be at least 0.5 and the binocular visual field at least 120° horizontally (minimum of 50° left and right) and 40° vertically (minimum of 20° up and down); no defects should be present within a radius of the central 20°.
If there is doubt about whether the visual requirements are met, the driver must be examined by a specialist. While it is relatively straightforward to determine the BCVA, an accurate assessment of the visual field implies the use of perimetry. In this regard, an important topic is left out of the directive: which perimetry algorithm should be used and how should its results be interpreted in terms of a passed or failed test? Omitting this brings risk for varying visual field standards. For instance, there are differing practices in the five Nordic countries, and although the UK and Norway both use the Esterman programme to determine driving eligibility in the case of visual field loss, the results are interpreted more leniently in the UK.4 5 Consequently, similar visual fields may be judged differently. Despite the best of intentions to improve road safety, the EU legislation thereby challenges the right of European drivers for legal equality.
The purpose of this study was to provide an overview of how the European visual field standards for driving are applied and determine whether individuals with visual field defects are treated equally across the member states of EU and European Free Trade Association (EFTA) and the UK.
Materials and methods
This was a survey study. The participants were ophthalmic healthcare professionals with special competence in visual standards for driving. One expert from each of the 27 EU member states, the 4 EFTA member states (Iceland, Liechtenstein, Norway and Switzerland) and the UK was invited to participate. Except for the UK and Norway, the experts were selected by asking each national ophthalmology society to recommend a specialist with high competence in visual standards for driving. In the UK and Norway (our own countries), we invited an expert who was independent of our study group. The survey data were collected from January to April 2021.
The experts responded to an electronic questionnaire, which anonymously presented monocular 30° threshold perimetry (the Octopus G programme) and binocular Esterman perimetry results of 15 cases of visual field defects affecting both eyes. The cases were selected by purposive sampling of patients who were referred to the Department of Ophthalmology at Oslo University Hospital for assessment of fitness to drive and included examples in the range from mild to severe visual field loss. The patients were also examined with a new binocular suprathreshold test, the European Driving Test Group 1 (EDT1), which adheres to the European visual field requirements for group 1 driving licenses.5 The experts were blinded to the EDT1 results. To ensure reliable perimetry examinations, trained ophthalmic nurses supervised the tests and no more than three false answers were allowed. Threshold perimetry was performed first. Esterman and EDT1 perimetry were then performed in random order.
The experts were asked to classify each case as either passed or failed in reference to their national visual standards for driving and on the premises that the perimetry results were reproducible, and that the visual acuity requirement (binocular BCVA of at least 0.5) was met. None of the experts participated in an actual assessment of fitness to drive, that is, their setting was hypothetical. The experts were also asked about whether their national guidelines endorsed a particular perimetry algorithm for assessing fitness to drive in the setting of visual field loss and whether pass/fail criteria were specified. The information provided in the electronic questionnaire is available as online supplemental information.
Fleiss’ kappa analysis was used to determine the inter-rater agreement between the experts. The results are otherwise presented with descriptive statistics.
Results
Twenty-five of 32 European countries responded to the survey. There was full pass/fail agreement in 3 of the 15 cases of visual field loss; cases 11, 12 and 13 were passed by all experts. Full agreement on a failed case was not reached. Figure 1 shows one of the cases (number 15) that caused strong disagreement, with a pass/fail proportion of nearly 50:50. Denmark graded most leniently and passed 12 of the 15 cases. Bulgaria, Romania and Slovakia graded most strictly and passed 5 of the 15 cases. The Fleiss’ kappa score was 0.52 (95% CI 0.49 to 0.55), indicating a ‘moderate’ level of agreement between the national experts.6Figure 2 shows the relationship between Esterman score and passed proportion for the 15 cases.
Monocular 30° threshold perimetry (A, B),binocular Esterman (C)perimetry and European Driving Test Group 1 (EDT1) perimetry (D) of case 15 (a patient with bilateral glaucoma more advanced in the right eye). The case was passed by 16 experts and failed by 9 experts. At least three adjacent missed test points within 20° or at least nine missed test points within 120°×40° defined a failed EDT1 result in the study, and the patient thus passed the EDT1 test. Notice that the test points are differently placed for EDT1 and Esterman; EDT1 has more central test points and the same number of test points in the upper and lower hemisphere, whereas Esterman extends to 80° horizontally. Accordingly, the EDT1 and Esterman findings are not identical. OS, left eye; OD, right eye.
Scatter plot with line of best fit displaying the relationship between Esterman score and passed proportion for the 15 cases in the study (larger dots represent two cases). A passed proportion of 0 or 1 indicates full agreement between the 25 European experts (case failed or passed by all experts, respectively).
Fourteen of the 15 cases were also examined with the EDT1. Slovenia reached the same pass/fail conclusion as the EDT1 in all the 14 cases and was hence in full agreement with the EDT1. Conversely, Greece reached the same pass/fail conclusion as the EDT1 in 7 of the 14 cases. Table 1 displays the pass/fail conclusion and level of agreement with the EDT1 for each case per country. It should be noted that experts with the same proportion of passed cases may disagree about which cases to pass. For instance, both the Greek and Slovenian expert passed 9 of 15 cases, but only the Slovenian was in full agreement with the EDT1. Because case 14 was lost to follow-up, an EDT1 result was not available for this case.
Table 1
|
Pass/Fail conclusion and level of agreement with the European Driving Test Group 1 (EDT1)
Fifteen of 25 countries endorsed specific perimetric tests for assessing fitness to drive in the setting of visual field loss. Three countries used the Esterman programme, two countries used threshold perimetry and nine countries used a combination of threshold perimetry and the Esterman programme. Five of these 15 countries also defined pass/fail criteria for the endorsed tests. Austria endorsed a special perimetric test, the Führerscheingutachten (FG) programme, which was not presented in this study. In 10 of 25 countries, national guidelines did not recommend a particular test. Table 2 gives an overview of the endorsed perimetric tests for assessing fitness to drive among the 25 countries.
Table 2
|
Endorsed perimetric tests for assessing fitness to drive in the setting of visual field defects, according to national guidelines
Table 3 shows the pass/fail criteria in the five countries that defined such. It should be noted that the Danish guidelines were issued by the Danish ophthalmology society, not the state authorities.
Table 3
|
Pass/Fail criteria, according to national guidelines
Discussion
The Commission Directive 2009/113/EC defines the European visual standards for driving, which all EU member states must incorporate into their national laws. Yet, the directive fails to establish a uniform approach to the visual field requirements. This survey study shows that there is only a moderate level of agreement for determination of pass/fail between national experts. As shown in figure 2, there was generally high agreement for the cases with best and worst visual fields, which were passed and failed by most experts respectively. However, for Esterman scores between 80 and 90, there was disagreement for several cases, reflecting that borderline visual fields in particular cause controversy about fitness to drive. The study also shows that the directive is enforced differently between European member states through the use of a variety of perimetry programmes and that few countries define pass/fail criteria. Consequently, identical visual field loss can result in either revocation or approval of a driving license. This is a breach of Article 20 of the Charter of Fundamental Rights of the EU, which states that everyone is equal before the law.7
Unrestricted movement of people across the internal borders of the Schengen Area is a fundamental principle in Europe. European citizens frequently cross these borders by car, which requires each member state to recognise driving licenses issued by the others. In this regard, the disagreement in this study poses a dilemma: a driver with visual field loss may meet the visual standard of his or her home country but not those of another. For instance, case 2 in the study fulfilled the visual field requirements in Denmark but not in Norway, and a Danish driver with this visual field would in principle be legally prohibited from driving in Norway. This raises concern about foreign jurisdiction, undermining the very idea of free movement within Europe from the perspective of its drivers.
In practice, the issue of visual field standards for driving is inseparable from the choice of perimetric test. Judgement of a visual field will indisputably depend on how it was measured. Also, for a given test specific pass/fail criteria are necessary to avoid ambiguity, such as in the case of the Esterman programme used in Ireland, the UK and Norway, as shown in table 3. While omitted from the Commission Directive 2009/113/EC, the underlying report by the Eyesight Working Group underscores the need for a uniform traffic perimetry algorithm to make certain that the visual field is consistently evaluated.8 The report even describes specifications and pass/fail criteria of such an algorithm, which overall, should be a static, suprathreshold programme that examines the binocular visual field. The EDT1 adheres to these specifications and will be available in the upcoming software upgrade for the Octopus 900 perimeter from Haag-Streit. EDT1 provides a tool for validating the current legislation and will hopefully be a step towards guidelines and recommendations supported by better evidence. Availability of widefield perimeters is also an issue to be resolved before actual visual field standards become a reality in Europe.
Limitations
This study is subject to several limitations. First, it should be noted that we only invited one expert per European country to participate in the study. For a country with precise visual field standards, the expert’s responses expectedly represent the general perimetry practice. This is the case for Norway, for instance, in which national guidelines leave little doubt about when to pass or fail a visual field. However, the survey revealed that 40% of the responding countries lacked national guidelines on assessment of the visual field. Although all experts were specifically tasked with responding for typical perimetry practice for their country, it is possible that responses from experts lacking national guidelines first and foremost represented personal practice. While we conclude that the EU directive fails to establish a uniform approach to the visual field requirements, we want to point out that the failure probably asserts itself at two levels: nationally and internationally. The degree of inter-rater disagreement at a national level, in particular where national guidelines lack, is a topic for future study. Second, it should be noted that because Austria endorsed a special perimetric test, the FG programme, which was not included in this study, the pass/fail conclusion of its national expert may be inaccurate. Finally, we acknowledge that the experts were tasked with judging a combination of perimetry algorithms that did not accurately adhere to the visual field standards for driving. In the review process, for instance, our choice of threshold test was questioned, and we agree that the Octopus G programme is not ideal for determining whether the central visual field standards are met. Instead, it would be better if we had a threshold perimetry programme that specifically examined the central 20° with a sufficient number of test points. One can raise the same concern about using the Esterman programme to determine whether the peripheral visual field standards were met. At the end of the day, this underscores that the issue of visual field standards is inseparable from the choice of perimetric test, and unless the test and standards adhere, disagreement is inevitable. Other combinations of perimetry algorithms may have brought different results in our study.
In conclusion, this European survey study of visual field driving assessment shows disagreement in determination of pass/fail across a range of mild to severe visual field loss, as well as wide variance in perimetry programmes chosen. Further work is required to reach consensus on perimetry programme choice and pass/fail criteria.