Retinal embolic events: frequency and impact following transcatheter aortic valve implantation (TAVI) for aortic stenosis

BMJ Open Ophthalmol. 2017 Jul 5;1(1):e000033. doi: 10.1136/bmjophth-2016-000033. eCollection 2017.

Abstract

Objectives: Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with severe symptomatic aortic stenosis. It has a cerebrovascular accident rate of about 5% but the effect on retinal embolic events has not been previously reported. This study investigated the occurrence of retinal emboli following TAVI.

Methods and analysis: In this prospective observational study, 20 patients underwent full ophthalmic examination to assess retinal embolic events prior to TAVI and at 48 hours and 1 month post-TAVI.

Results: At 48 hours post-TAVI, one patient had a new cotton wool spot in the right eye. At 1 month, another two patients had new retinal emboli events in at least one eye and a fourth patient developed retinal splinter haemorrhages in the right eye.

Conclusion: Retinal embolic events and new retinal abnormalities following TAVI occurred in 15% and 20% of our cohort, respectively, without any associated retinal damage or significant visual problems. Retinal evaluation may be a useful surrogate test for cerebral embolisation in future studies assessing the utility of new valve prostheses and embolic protection devices.

Keywords: imaging; retina.